- Industrial Hygiene
- Environmental
- Analytical Laboratory
- Disc Filter Membrane
- Glass Fiber
- Silver Filter Membrane
- Ceramic Filter Membrane
- Aluminum Oxide Filter Membrane
- Mixed Cellulose Ester (MCE) Filter Membrane
- Nylon Filter Membrane
- Polytetrafluorothylene (PTFE) Filter Membrane
- Cellulose Acetate (CA) Filter Membrane
- Hydrophilic Polycarbonate (PCTE) Filter Membrane
- Hydrophobic Polycarbonate (PCTE) Filter Membranes
- PVDF Filter Membrane
- Polypropylene (PP) Filter Membrane
- Polyethersulfone (PES) Filter Membrane
- Polyacrylonitrile (PAN) Filter Membrane
- Hydrophilic, Polyester Track Etch (PETE) Filter Membrane
- Hydrophobic Polyester (PETE) Filter Membrane
- Polyether Ether Ketone (PEEK) Filter Membrane
- Regenerated Cellulose (RC) Filter Membrane
- Quantitative Filter Paper
- Qualitative Filter Paper
- Syringe Filter
- In-line Filter
- Botanical Filter Paper
- Microbiology
- Others
- Disc Filter Membrane
Inter Products Marketing Sdn Bhd
Klang, Selangor, Malaysia.
+6016-305 9138
Sonus GA116B Sound Level Meter, Class 1
Previous | 8 / 11 | Next |
Castle / GA116B
Sonus GA116B Sound Level Meter, Class 1
The entry level of the Castle Pocket Range of Sound Level Meters is the SONUS B(GA116B ), a feature packed, pocket instrument that is fully compliant with IEC 61672-1:2013. This meter gives simultaneous sound pressure (Lp) and peak (Cpeak) measurement for a multitude of tasks including initial spot-check assessments to the Control of Noise at Work Regulations 2005. It has a high-specification measurement microphone and is cased in tough, crack resistant ABS plastic.
Technical Specification
Applicable Standards | IEC 61672-1:2013 (Integrating, Sound Exposure and Sound Level Meters) |
Microphone and Preamplifier | Type 2 Pre-Polarised ½” (13.2 mm) Electret Free-Field, Electret Condenser Microphone: 20Hz – 8KHz ± 2dB –32 dB ± 3 dB re 1V/Pa Custom pre-amplifier design Typical actuator to free-field correction factor (based on 500Hz=0) is shown below |
Display | Back-lit LCD panel (8x1 Characters) |
Alpha-Numeric display for measured results | |
Level Range | Measuring Range: 35-140 |
Linear operating range (IEC61672-1): 65dB | |
3 Measurement Ranges (IEC61672-1): 35-100 | |
55-120 - Reference Range | |
75-140 | |
Noise Floor | Typical ’A’ Weighting <32 dB(A) rms. |
‘C’ Weighting <38 dB(C) rms. | |
Frequency Weighting | ‘A’ and ’C’ to IEC 61672-1:2002 and IEC 60651:1979+A1+A2 |
Frequency Range | 20 Hz - 8 kHz (including microphone) |
1 Hz - 20 kHz (electrical characteristics) | |
Time Weighting | Slow and Fast |
Instrument Response | Simultaneous rms. and Peak |
Measurement Parameters | Lp (Sound Pressure Level), Lmax (maximum Level), Cpeak (Max. Peak Level) |
Other Displays: Elapsed time, Overload, Battery Life | |
Calibration | Software controlled 91.0 to 120.0 dB (1kHz) in 0.1 dB steps |
Processing | A to D Converter: 12-bit |
Controller: 8MHz, micro-controller | |
Power Requirements | Batteries: 1 x 6LR61 (size PP3), Life: >12 hours (alkaline batteries, continuous operation). |
Dimensions | 60mm (width) x 35mm (depth excluding pocket clip) x 135mm (height without microphone) or 210mm (height with microphone) |
Weight | 220gms (including battery) |
Manuals | Multi-language manuals*: French, German, Spanish and Italian. |
Accessories
GA601 Single Level Calibrator:
KA010 Kit Case for GA116B, GA601 and Accessories